Project Overview
This is a waste gas treatment project for the painting workshop of Beijing North Vehicle Group. The exhaust gas is typical large-air-volume and low-concentration coating VOCs, mixed with paint mist, benzene series and volatile organic solvents. The original water curtain direct discharge process is upgraded to a complete advanced treatment system.
Core Parameters
- Total treatment air volume: 60,000 m³/h
- Inlet VOC concentration: 200 mg/m³
- Discharge standard: ≤50 mg/m³
- Operation mode: 24-hour continuous operation, 300 working days per year
Process Flow
Multi-stage Dry Filter → Zeolite Concentration Rotor → CO Catalytic Oxidizer → Plate Heat Exchanger → High-altitude Discharge
Pretreatment: Four-stage graded filters (G3/G4/F9) intercept paint mist and solid particles to prevent blockage of rotor micropores.
Concentration Unit: The hydrophobic zeolite rotor with a concentration ratio of 20:1 converts large-air-volume low-concentration waste gas into small-air-volume waste gas to reduce the load of subsequent equipment.
Catalytic Oxidation: The desorbed high-concentration gas enters the CO unit and is completely oxidized at 210~500°C with the action of noble metal catalyst.
Waste Heat Reuse: The plate heat exchanger recovers flue gas heat to supply heat for rotor desorption and cut down energy consumption.
Main Equipment
- Multi-stage bag filter
- Hydrophobic zeolite concentration rotor
- CO catalytic combustion unit
- Plate heat exchanger
- Explosion-proof variable frequency fan
- PLC automatic control system
Operation Performance
The VOC removal efficiency is over 90%, and all particulate indicators comply with DB11/1226-2015 (Beijing Local Standard). The incombustible zeolite material has a service life of 8~10 years with low failure rate. Equipped with multiple safety interlocks for over-temperature, over-pressure and fan fault.
Technical Highlights
- The combination of graded filtration and hydrophobic zeolite solves the common problem of paint mist blockage in the coating industry
- Integrated concentration and catalytic process balances treatment effect and operating cost with excellent energy-saving performance
- The whole equipment adopts ExDIIBT4 explosion-proof grade and IP55 protection grade, which is suitable for hazardous areas of painting workshops