Industrial vapor recovery and air pollution control equipment background

Sanjiang Energy – Oil Tank Farm Mixed Waste Gas Treatment (CO)

Project Overview

This project serves Sanjiang Energy, aiming to treat mixed waste gas from coal tar, diesel and naphtha storage tanks. The exhaust gas still contains medium and high concentration VOCs after condensation pretreatment with complex components. The equipment is required to operate continuously for a long time and adapt to fluctuating working conditions.

Core Parameters

  • Total treatment air volume: 2,000 m³/h
  • Average VOC concentration: 3.6 g/m³
  • Annual operation hours: 8,000 hours

Process Flow

Flame Arrestor → Gas Mixing Chamber → Electric Heater → CO Catalytic Reactor → Plate Heat Exchanger → Chimney Discharge

Safety Pretreatment: Mixed tank gas passes through the flame arrestor to block flame propagation.

Heating & Reaction: The waste gas is preheated and enters the fixed-bed catalytic reactor for low-temperature oxidation of organic compounds.

Heat Recovery: High-temperature flue gas recovers waste heat via heat exchanger to reduce auxiliary heating power.

Standard Discharge: Purified gas is discharged through a 15m-high chimney.

Main Equipment

  • Flame arrestor
  • Electric heater assembly
  • CO catalytic reactor
  • Honeycomb noble metal catalyst
  • Plate heat exchanger
  • Explosion-proof fan
  • 15m exhaust chimney

Operation Performance

The outlet VOC concentration is less than 20 mg/m³, complying with GB 31571-2015. The total system pressure drop is below 5 kPa with smooth air flow and low noise. Complete emergency vent interlock is equipped for abnormal conditions.

Technical Highlights

  • Skid-mounted modular design with small footprint, convenient installation, commissioning and maintenance
  • Low-temperature catalytic reaction generates extremely low NOx with superior environmental performance
  • Customized for oil tank farms, adaptable to frequent fluctuations of gas volume and concentration

How a catalytic oxidizer works on tank farm vapour

Tank farm vapour is a mixture of hydrocarbon vapours displaced from storage tanks during filling, plus vapour generated by temperature change. Condensation removes the heavier fraction, and the catalytic oxidizer then destroys what remains at a bed temperature far below the flame temperature of thermal oxidation.

The reason a catalytic route suits this duty is autothermal operation: above a certain inlet concentration the oxidation of the VOC itself releases enough heat to hold the bed temperature, so no supplementary fuel is needed. Below that concentration the unit needs external heat, and the economics change.

What decides whether a catalytic route is viable

  • Inlet concentration after pretreatment — too low and the unit needs fuel; too high and the temperature must be controlled to protect the catalyst.
  • Catalyst poisons in the stream — sulphur compounds, halogens, heavy metals and silicones deactivate the catalyst. Coal tar and naphtha service makes this the first question to answer, not the last.
  • Particulate and aerosol carry-over — condensed droplets blind the catalyst surface; the pretreatment has to be reliable, not nominal.
  • Duty cycle — continuous operation at stable load is what makes the autothermal saving real; frequent starts erode it.

What to specify for a similar installation

  1. Total treatment air volume and the range of variation, not only the design point.
  2. Inlet VOC concentration and composition, including sulphur species.
  3. Annual operating hours and the expected load profile.
  4. Required outlet concentration and the applicable emission standard.
  5. Pretreatment provided upstream, and its guaranteed performance.
  6. Plot area, utilities and the electrical supply available.

Frequently asked questions

Why does the concentration matter more than the airflow?

Because autothermal operation depends on the heat released per unit of gas, which is a function of concentration. Two streams of the same airflow can sit on opposite sides of the fuel-free operating point.

How is the outlet concentration guaranteed?

By the catalyst volume, the bed temperature and the residence time together, verified by testing at commissioning. A guarantee without those three defined is not a guarantee.